Features

  • Built-in column temperature control box for accurate experimental results
  • Capable with Flash column for rapid detection of anions and cations
  • Intelligent flow path clearing system for easy cleaning
  • Real time display
  • Wi-Fi connection for convenient data transfer
  • Continuous, non-stop 10 hours working system
  • Easy to operate

Ion Chromatograph LD-LPIC-A10

Ion ChromatographLD-LPIC-A10is a light weight, portable design model with powerful data processing system. The quick ion chromatograph columns are used for rapid 5 min detection. Adopted with built –in multi-channel solvent selection valve helps in gradient elusion, it shortens peak time, and improves efficiency of the chromatograph conducted. Upgraded with dual detection system (dual column for various applications), supports the needs of different industries.

SKU Code: LD-LPIC-A10

Also Available in below capacities

Chromatographic Pump : Type : High-pressure and low –pulse double plunger tandem advection pump
Built-in Heat conduction type column heater : Temperature range : Room temperature +5°C to 60°C (41 to 140°F)
Electromagnetic injection valve : Maximum pressure : 35 MPa
Digital and temperature control detection system : Type : Temperature control and bipolar conductivity detector
Flow system : Plastic path flow : Made of PEEK material
Panel computer : Display screen : 12.3 inch
External size (L × W × H) : 440 × 226 × 420 mm
Weight 786 g
Flow Range 0.001 to 9.999 mL/min
Net weight 8 kg
Cell volume ≤ 0.8 µL
Flow system
Plastic path flow
Control mode By stepper motor
Gross weight 11 kg
Power supply 24 V (DC)
Flow accuracy ± 0.5 %
Six way valve PEEK material pressure 5000 psi, independent automatic collecting and flow function
Baseline drift ≤ 20 % FS/30 min
Baseline noise ≤0.5 % FS
Detection type Bipolar conductivity detection
Output voltage -6000 to 6000 mV (adjustable)
Panel computer
Display screen
Internal memory 2G
Maximum Pressure 35 MPa (PEEK)
Maximum pressure 10 MPa
Measurement range 0 to 45000 µ S/cm (adjustable)
Temperature range Room temperature +5°C to 60°C (41 to 140°F)
Flow Repeatability RSD ≤ 0.1%
Allowable deviation ± 1°C
Chromatographic Pump
Type
Detection resolution ≤ 0.0020 nS/cm
Instrument linearity ≥ 0.999
Temperature accuracy ± 0.01°C
Temperature stability ≤ 0.5°C/h
Qualitative Repeatability ≤2 %
Quantitative Repeatability ≤0.5 %
External size (L × W × H) 440 × 226 × 420 mm
Electromagnetic injection valve
Maximum pressure
Built-in Heat conduction type column heater
Temperature range
Digital and temperature control detection system
Type
Used for on field selective analysis of organic and inorganic ions, also used in quality and research laboratories across pharmaceutical, water quality, chemical industries.