Features

  • High precision automatic optical system
  • Graphite furnace temperature control
  • High technical indicators
  • Deuterium lamp for background correction system
  • Polymer automization chamber
  • Powerful, intelligent user-friendly design
  • Automatic analysis & Sampler

Atomic Absorption Spectrophotometer LD-LAAS-A22

Atomic Absorption spectrophotometer comes with flame, graphite furnace and hydride generation system to meet different customer demand. It is provided with deuterium hollow cathode lamp to eliminate the interference of molecular absorption and Titanium Burner to improve the analysis efficiency and accuracy of the flame. The autosampler has integrated graphite furnace design with high-precision syringes to enter volume as minimum as 0.5μl with intelligent online dilution and concentration function. It has great applications research and medicine, environmental science and other industries.

SKU Code: LD-LAAS-A22

Also Available in below capacities

Wavelength range : 190 - 900 nm
Wavelength range : 180 - 900 nm
Wavelength range : 180 – 900 nm
Wavelength range : 180 – 900 nm
Wavelength range : 190 nm ~ 900 nm
Working spectral range : 190 to 900 nm
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Detector imported photomultiplier tube
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision RSD ≤ 0.5
Gas Control Automatic gas control system
Lamp holder ≤ 6 lamps automatic turret, automatic alignment
Measurement Flame method, Hydride generation-Atomic absorption method
Sample Tray 70 sample cups, 6 reagent cup
The Program Automatic temperature control up to 20 order
Heating Mode vertical heating
Power supply 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA
Ignition Type Microcomputer control, automatic ignition
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
Sample Volume 1 - 100 μl
Optical System Large 1800 /mm grating ruling, full closed optical system
Detection Limit 0.4 × 10-12g (Cd)
Absorbance Range 0 - 4 A
Wavelength range 180 – 900 nm
Temperature Range room temperature to 3000 ℃
The Cooling Water Can choose cooling water circulation system
Spectral Bandwidth 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
Atomization Chamber Polymer explosion-proof spray chamber
Temperature Control The furnace enriched up to 20 times
Wavelength accuracy ≤ 0.15 nm
Detection Limit (Cu) 0.002 μg/mL
The volume of sample better than 1 %(at the time of 10 mL - 100 mL)
Characteristics Volume 0.5 × 10-12g (Cd)
Lamp power supply mode pulsed power supply
The Smallest Lincrement 0.1 μl
Wavelength repeatability ± 0.1 nm
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
Temperature Control Method Vertical optical temperature monitoring graphite tube wall temperature
Repeated Sampling Frequency up to 99 Times
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Cleaning and waste container volume Each 500 mL
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Atomic Absorption spectrophotometer is used in scientific research, quality control, disease control, environmental protection, metallurgy, agriculture, chemical industry, and analysis of samples, equipment maintenance, simple and convenient.

Similar Products