Features

  • Ferrotec Peltier cooler with improved efficiency and long life
  • Wide range of block temperature (4-105°C) with SOAK low temperature function
  • 4 individual filters cover wide range of fluoresence detection wavelength
  • Easy data transfer via USB and Bluetooth
  • Real time fast double wavelength X-Y scan system
  • High long life LED
  • Dual high sensitivity PMT (photomultiplier tube) synchronous detection
  • Panoramic view of experimental results

Real Time PCR LD-LRTP-B20

Real time PCRLD-LRTP-B20comes with 96 well capacity PCR machine with, 1 to 36°C gradient temperature range, and fast speed dual colour scanning mode. Its wide fluorescence wavelength range with innovative 4 channel design, optimizes thermal performance and maximizes convenience during operation. With its unique block dissipation technology, it provides precise temperature control and thermal gradient which easily optimizes PCR assays.

SKU Code: LD-LRTP-B20

Also Available in below capacities

Sample Capacity : 12 × 8 (96 wells with 0.2 ml each) plate, 96 × 0.2 ml tubes (Bottom Transparent)
Sample Capacity : 96-Well PCR plate12 × 8-strip
96 × 0.2 ml(Bottom Transparent)
Sample Capacity : 96-Well PCR plate12 × 8-strip
96 × 0.2 ml(Bottom Transparent)
Sample Capacity : 96-Well PCR plate12 × 8-strip
96 × 0.2 ml(Bottom Transparent)
Sample Capacity : 48 × 0.2 ml
Sample Capacity : 48 × 0.2 ml
Socket RS 232C Adapter
Program Max 20 Segments for Each Program, Max 99 Cycles
Scan Mode Entire Plate or Designated Line
Scan Period 5.5 sec
Power Supply 100 to 240 V, 50/60 Hz, 600 W
Ramping Rate 4.0 ℃/sec
Dynamics Range 10 to 1010 Copies
Operation Mode Continuous
PC Configuration Memory : 512 M; Hard Disk : 10 GB; CPU : Pentium® 4; Virtual Memory : ≥ 1000 MB
Temp. Uniformity ≤ ± 0.3 ℃
Block Temp. Range 4 to 105℃ (Minimum Increment: 0.1℃), SOAK Low Temp. Conservation Function
Temp. Fluctuation ≤ ± 0.1 ℃
Temp. Control Mode BLOCK/Tube Simulation Mode (Automatic Control based On Sample Volume )
Emission Wavelength 500 to 800 nm
Hot-lid Temp. Range 30 to 110℃ (Adjustable, default 105℃, Automatic Hot-lid )
Sample Volume Range 5 to 100μl
Gradient Temp. Range 1 to 36 ℃
Excitation Wavelength 300 to 800 nm
Temp. Control Accuracy ≤ ± 0.1 ℃
Detected Fluorescence F1 : FAM, SYBR Green 1; F2 : VIC, HEX, TET, JOE; F3 : CY3, NED, TAMRA; F4 : ROX,TEXAS-RED
Dimension ( L × W × H ) 430 x 395 x 352 mm
Max. channels number of fluorescence detection 4 channels
Real time PCR, used in quantification and characterization of nucleic acids in academic institutes, research centres, diagnostics and laboratories.