Automatic Coagulation Analyzer LD-LCAZ-B10 is a compact and benchtop unit, adopted with Optical coagulation assay, and immunoassay methodology with 4 test channels, 40 cuvette and 10 positions for sample and reagent container each. Features automated functions for sample probe cleaning, sampling procedures, measuring and data analysis, and re-testing of abnormal samples with error reporting. Designed with bar-code and QR code scanning, remote control function and LCD display, this coagulation analyzer saved calibration curves and test results with data memory for more than 50 million pieces of data. With continuous working time for up to 24 h and automatic or manual test mode, it has system maintenance settings along with motor frequency settings and motion accuracy setting. Equipped with self-testing and editable settings for calibrations and quality control, and test procedure, this unit provides emergency sample setting function for any sample position with liquid level detection
SKU Code: LD-LCAZ-B10
Power | ≤ 320 VA |
Method | Optical coagulation assay, and immunoassay |
Cuvette | 40 |
Display | LCD display or touch screen |
Storage | More than 50 million pieces of data |
Linearity | FIB linearity r ≥ 0.975 D-dimer linearity r ≥ 0.975 |
Net Weight | 39 kg |
Test items | Prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (FIB), coagulation factors II-XII, D-dimer, reptilase time (RT), lupus anticoagulant (LA), heparin (HEP), protein C (PC), etc. |
Test speed | PT - 300 Tests/h, APTT - 250 Tests/h, TT - 300 Tests/h, FIB – 300 Tests/h |
Gross weight | 75 kg |
Power supply | AC 220 ± 22 V AC, 50 ± 1 Hz |
Test methods | Automatic or manual test mode |
Relative Bias | FIB relative bias ≤ ±10.0%; D-dimer relative bias ≤ ±10.0% |
Repeatability | CVPT ≤ 2% CVAPTT ≤ 2.5% CVTT ≤ 3% CVFIB≤5% CV D-Dimer ≤ 6% |
Sample volume | PT, APTT, TT, FIB, FCT: 5 to 100 μL |
Test channels | 4 |
Reagent volume | PT, APTT, TT, FIB, FCT: 5 to 200 μL |
Preheating time | >30 mins (after start up) |
Sample position | 10 |
Test timing range | 0 to 300 s |
Temperature control | Test module and preheating system: 37℃ ± 1℃ (constant temperature control) Reagent cooling temperature control: >16℃ |
Constant temperature | Detector: 37℃ ± 1℃, Reagent and Sample disk: 37℃ ± 1℃ |
Sample carryover rate | FIB carryover rate ≤10% |
Continuous working time | ≥ 24 h |
Reagent container position | 10 |
Packaging dimension (W×D×H) | 820×730×740 mm |
Automatic Coagulation Analyzer is used to perform coagulation tests as well as chromogenic and immunologic assays, to measure a coagulation pathway speed, as well as thrombolin and thromboplastin levels, and for detection of blood coagulation factor in medical care, scientific research and education institutions etc. |