Octane Number and Cetane Number TesterLD-LOCT-B10is a portable device for rapid petroleum products quality monitoring in fields and lab environment conditions. Glass detector has a built in element sensitive to fuel sample temperature detection. The instrument electronic computing module processes detector signals, performs all necessary calculations, and constantly tests the main function modules. It is ideal used in the determination of octane, cetane numbers, our point depressants and break down time in the oil and petroleum industries.
SKU Code: LD-LOCT-B10
Dimension | 100 × 210 × 40 mm |
Net Weight | 0.68 kg |
Gross weight | 0.85 kg |
Sensor 1 and 2 | 60 × 100 mm |
Voltage supply | 5.4 V |
Antiknock range | 0.5 to 15 % |
Time measurement | 1 sec to 5 sec |
Relative humidity | 98 % RH |
Volume error limit | 0.03 |
Volume resistivity | 106 to 1014 Ohm |
Cetane number range | 20 to 100 CN |
Octane number range | 40 to 125 ON |
Storage temperature | 5°C to 40°C |
Voltage error limit | 1 kV |
Kerosene error limit | 0.03 |
Oil base error limit | 1 BN unit |
Petrol breakdown time | 50 to 2400 min |
Instrument useful life | 6 |
Kerosene content range | 0 to 50 % |
Oils base number range | 3 to 24 unit |
Oil clarity error limit | 50 to 100 % |
Maximum time error limit | 0.05 |
Water in oil error limit | 0.01 |
Water in oil content range | 0 % to 30 % |
Mechanical impurities range | 97 % to 100 % |
Oil loss angle tangent range | 0.01 to 40 % |
Dielectric permeability range | 1 to 5 units |
Diesel pour point error limit | 2˚C |
Maximum antiknock error limit | 0.001 |
Oil voltage measurement range | 5 to 100 kV |
Loss angle tangent error limit | 0.0001 |
Maximum parallel CN difference | ± 0.5 CN |
Maximum parallel ON difference | ±0.2 |
Pour-point depressants content | 0.2 to 1 % |
Maximum error limit cetane number | ±1.0 CN |
Maximum error limit octane number | ±0.5 ON |
Mechanical impurities error limit | 0.0001 |
Pour point depressant error limit | 0.0001 |
Maximum parallel voltage difference | 0.2 kV |
Maximum parallel oil clarity difference | 0.001 |
Maximum error limit dielectric permeability | 0.001 units |
Maximum parallel loss angle tangent difference | 0.001 units |
Maximum parallel dielectric permeability difference | 0.001 units |
Octane Number & Cetane Number Tester used in oil and petroleum industries for determination of octane numbers, cetane numbers, petrol breakdown time, antiknock compounds, pour-point depressants, oil clarity, dielectric permeability, kerosene content, oil volume resistivity, etc. |