Drug Stability Test ChamberLD-LDST-A21designed with 225 L internal capacity volume. It offers 20 to 98 % RH humidity range and temperature ranges from 0℃ to 100℃. Designed to simulate constant climatic conditions for testing a wide variety of pharmaceutical raw Drug material or finished Drug products for their quality, performance, shelf life and stability. It features conductive film located on the interior glass (of double layer 8 cm thick insulation glass) to prevent window frosting, built-in LED light for the work room lighting to clearly observe samples. A good temperature humidity chamber is essential for evaluating potential success or failure of a product in the field.
SKU Code: LD-LDST-A21
Heat load | 1000 W |
Controller | Programmable color LCD touch screen controller Ethernet connection, PC Link |
Humidifier | External isolation, stainless steel surface evaporation humidifier |
Net weight | 400 kg |
Refrigerant | R404A, R23 |
Cooling Rate | 1 ℃ / min |
Gross weight | 440 kg |
Heating Rate | 3 ℃ / min |
Power Supply | 220 V, 50 Hz / 380 V, 50 Hz |
Maximum Noise | 65 dBA |
Cooling system | Mechanical compression refrigeration system |
Humidity Range | 20% to 98% RH |
Air Circulation | Centrifugal wind fan |
Heating Element | Nichrome heater |
Humidity Sensor | Dry and wet bulb sensor |
Interior Volume | 225 L |
Dehumidification | Evaporator |
View Window Size | 250 × 280 mm |
Exterior Material | Steel Plate with protective coating |
Interior Material | SUS304 stainless steel |
Relative Humidity | ≤ 85% RH |
Temperature Range | 0℃ to 100 ℃ |
External dimension | 960 × 1150 × 1860 mm |
Internal dimension | 500 × 600 × 750 mm |
Observation Window | Interior lighting, double-layer thermo stability silicone rubber sealing |
Refrigerating unit | French TECUMSEH compressor |
Temperature Sensor | PTR Platinum Resistance PT100 Ω/MV A-class, accuracy 0.001℃ |
Thermal Insulation | Polyurethane foam and insulation cotton |
Ambient Temperature | 5℃ to +35 ℃ |
Build-in Water Tank | 270 × 300 × 400 mm |
Water supply system | Automatic water supply Water purification system |
Standard Configuration | 1 Cable hole (Φ 50,) with plug; 2 shelves |
Temperature Fluctuation | ± 0.5 ℃ |
Humidity Deviation in time | ± 2.5% RH |
Temperature Deviation in time | ± 2.0 ℃ |
Drug Stability Test Chamber is used in food industry also basic used in advanced research, Pharmaceutical Drug stability testing point, chemical industries, and including testing products relating to aerospace, electronics, automobile and environmental stress screening etc. |