Features

  • Large LCD display
  • 2 - 5 points calibration from low to high concentration
  • Direct ion concentration readout for elaborate measurement process
  • Selectable concentration units from ppm, mg / L, mol / L
  • mV measurements to check the performance of ion selective electrode
  • Temperature compensation provides accurate reading over the entire range
  • Stability indicator to show current measurement status
  • Calibration due reminder for regular calibration of the meter
  • Auto hold function to freeze stable reading for better viewing & recording
  • Automatic electrode diagnosis shows the slope of the sensor
  • Reset setting function
  • Expanded memory stores and recalls up to 500 readings
  • Built –in real time clock stamps
  • USB communication interface to transfer stored data to PC

Benchtop Ion meter forNO3, LD-LBIM-A29

Benchtop Ion meter for NO3, LD-LBIM-A29 comes with (NO3) nitrate ion selective electrode for nitrate ion concentration measurement. This Ion meter comes with 0.5 % F.S. measurement accuracy. Its direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.

SKU Code: LD-LBIM-A29

Also Available in below capacities

Ion measurement range : Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement range : F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement range : Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm
Ion measurement range : Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm
Ion measurement range : Br range: 5 × 106 - 1 M, 0.4 - 79900 ppm
Ion measurement range : NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm
Power DC 5 V, using AC adapter, AC 220 V / 50 Hz
Memory Stores up to 500 sets of data
Output USB communication interface
Display LCD (130 × 110 mm)
Weight 1.5 kg
mV Range (-1999.9) to 1999.9 mV
Connector BNC
Power Off Manual or automatic (10, 20, 30 minutes)
Resolution 0.001, 0.01, 0.1, 1, automatic
mV Accuracy ± 0.2 mV
mV Resolution 0.1 mV
Reset Function Yes
Calibration Due 0 to 31 days
Compensation Mode Manual or automatic
Calibration Points 2 to 5 points
Data Hold Function Manual or automatic endpoint detection
Stability Condition Low or high
Temperature Accuracy ± 0.5 °C, ± 0.9 °F
Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
Ion Measurement Range 0.4 to 62000 ppm
Temperature Resolution 0.1°C
Dimension (L × W × H) 210 × 188 × 60 mm
Ion Measurement Accuracy ± 0.5 % F.S.
Temperature Compensation 0 to 100 °C, 32 to 212 °F
Temperature Measurement Range 0 to 105 °C, 32 to 221 °F
Benchtop Ion meter is used to measure the cadmium ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.