Features

  • Common Features
  • Calibration due reminder informs operator to calibrate the meter regularly
  • Stability indicator displays the status of current measurement
  • Auto hold function freezes stable, final readings for better viewing and recording
  • Manual temperature calibration to rectify the deviations in temperature
  • Automatic temperature compensation for accurate measured value over the entire range
  • Selectable temperature units (°C or °F) for different application requirements
  • Expanded memory stores and records up to 500 readings
  • Help message as an operational guide, helps users for quick access to the parameters
  • Reset function automatically resumes all the setting back to factory default options
  • Store data is transferrable into computer via USB communication interface
  • pH mode
  • 1-5 points push button calibration to automatically identify pH buffer
  • Convenient to select pH buffer standard (USA/NIST/DIN) or custom
  • Automatic electrode slope display helps operator whether to replace the sensor
  • ORP mode
  • 1 point offset calibration to adjust the display value to known standard
  • Relative & absolute mV measurements for accurate ORP readings
  • Ion concentration mode
  • 2-5 points calibration, included with 8 concentration points for selection
  • Automatic recognition of ion electrodes, no need to specify type of ion
  • mV measurements mode for checking the performance of current ion electrode
  • Direct reading of concentration measurements to avoid critical conversation and calculations
  • Multiple concentration units to be suitable for various applications
  • Conductivity / TDS / Salinity / Resistivity Mode
  • 1-5 point for calibration with automatically identification of calibration solutions
  • Can select cell constant (0.1/1/10) and normalization temperature (20°C or 25°C)
  • TDS conversion factor, seawater, practical salinity measurements mode to meet different water quality measurement requirements
  • Linear or pure water compensation improves the measurement accuracy
  • Dissolved oxygen mode
  • 1-2 points calibration using the air-sealed water & zero oxygen solution
  • Manual salinity & barometric pressure compensation for accurate readings

Portable Multi-parameter Water Quality Meter LD-LMPWM-A10

Portable Multi-parameter Water Quality MeterLD-LMPWM-A10is adapted with different modes for measuring quality of water on different parameters such as pH, ORP, Ion, conductivity, TDS, salinity, dissolved oxygen content. Due to its portable design, it is suitable for outdoor measurements i.e. on site water testing, remote area water testing & for research purpose. It is reliable and user friendly.

SKU Code: LD-LMPWM-A10

Also Available in below capacities

pH mode :
Memory Stores up to 500 data sets
Output USB communication interface
Weight 300 g
pH mode
Accuracy ± 2.0 %
TDS factor 0.1 - 1.0 (default 0.5)
DO accuracy ± 0.2 mg/L
Resistivity
pH accuracy ± 0.002 pH
ORP accuracy ±0.2 mV
Power supply 3 × 1.5 V “AA batteries or DC 5 V power adapter
TDS accuracy ± 1 % F.S.
Cell constant K = 0.1, 1, 10 or user-defined
Ion accuracy ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)
Calibration due 0 to 31 days
Ion measurement
ORP measurement
Dissolved oxygen
TDS measurement
Measurement modes Seawater or practical salinity
Salinity accuracy ± 1 % F.S
Calibration points 1 - 2 points
Compensation modes Linear or pre water
Pressure correction 60.0 to 112.5 kPa, 450 - 850 mmHg
Salinity correction 0 to 50 g/L
Resistivity accuracy ± 1 % F.S
Salinity measurement
Stability conditions Low or high
pH calibration points 1 - 5 points
% Saturation of Oxygen 0.0 to 200.0 %
Conductivity accuracy ± 0.5 % F.S.
Ion calibration points 2 - 5 points
ORP calibration points 1 point
Resistivity resolution 0.01, 0.1, 1
Dimension (L × W × H) 185 × 88 × 32 mm
Temperature coefficient 0.0 to 10.0 % / °C
Conductivity measurement
Temperature compensation 0 to 100 °C, 32 to 212 °F, Manual or Automatic
pH calibration solutions USA, NIST, DIN or user defined
Ion calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L
Normalization temperature 20 °C or 25 °C
ORP calibration solutions mV & relative mV
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
The portable multi-parameter water quality meter is used for quality testing of water on different parameters in research and development labs, water resources and plants in nearby or remote area.