Benchtop Multi-parameter Water Quality Meter LD-LMPWM-A43
Benchtop Multi-parameter Water Quality Meter LD-LMPWM-A43 with large backlit LCD (125 × 100 mm) display, measures pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and dissolved oxygen. Equipment saves space of the benchtop by combining multiple parameters in one unit. With expanded memory, it stores and recalls up to 500 data sets. Calibration due reminder informs the operator to calibrate the meter regularly. Setup menu allows you to set the number of calibration points, stability criteria, temperature unit, date and time, auto-power off, etc. USB communication interface for data transfer and timed interval readings.
SKU Code: LD-LMPWM-A43
Also Available in below capacities
- Specifications
- Product Applications
|
|
pH Mode |
pH Range : -2.000 to 20.000 pH | pH Accuracy : ±0.002 pH | pH Resolution : 0.001 / 0.01 / 0.1 pH, selectable | pH Calibration Points : 1 to 5 points | pH Buffer Solutions : USA / NIST / DIN / 2 custom buffers |
|
TDS Mode |
TDS Range : 0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt | TDS Accuracy : ±1% F.S. | TDS Conversion Factor : 0.1 to 1.0 (default 0.5) | TDS Resolution : 0.01, 0.1, 1, automatic |
|
Temperature |
Temperature Measurement Range : 0 to 105 °C / 32 to 221 °F | Temperature Measurement Accuracy : ±0.5 °C / ±0.9 °F | Temperature Measurement Resolution : 0.1 °C/°F | Temperature Measurement Calibration Points : 1 point (calibration range- Reading ±10 °C/°F) |
|
Conductivity |
Conductivity Range : 0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm | Conductivity Accuracy : ±0.5% F.S. | Conductivity Resolution : 0.001, 0.01, 0.1, 1, automatic | Conductivity Calibration Points : 1 to 5 points | Conductivity Solutions : 10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS | Conductivity Temperature Coefficient : 0.0 to 10.0% / °C | Compensation Mode : Yes (Linear and pure water) | Cell Constant : K=0.1, 1, 10 or Custom | Reference Temperature : 20 or 25 °C |
|
ORP(mV) Mode |
mV Range : -1999.9 to 1999.9 mV | mV Accuracy : ±0.2 mV | mV Resolution : 0.1 / 1 mV, selectable | mV Calibration Points : 1 point | Measurement Modes : Relative / Absolute mV |
|
Salinity Mode |
Salinity Range : 0.00 to 80.00 ppt / 0.00 to 42.00 psu | Salinity Resolution : 0.01 | Salinity Accuracy : ±1% F.S. |
|
Resistivity Mode |
Resistivity Range : 0.00 to 20.00 MΩ | Resistivity Resolution : 0.01 | Resistivity Accuracy : ±1% F.S. |
|
Ion Concentration |
Ion Concentration Range : 0.001 to 19999 ppm, mg/l, mol/l, mmol/l (depending on the range of ISE) | Ion Concentration Accuracy : ±0.5% F.S. (monovalent), ±1% F.S. (divalent) | Ion Concentration Resolution : 0.001, 0.01, 0.1, 1, automatic | Ion Concentration Calibration points : 2 to 5 points | Calibration Solutions : 0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000 |
|
Other Specifications |
Temperature Compensation Range : 0 to 100 °C / 32 to 212 °F manual or automatic | Data Hold Function : Manual / Auto-read measurement endpoint | Stability Criteria : Low / High | Calibration Due Alarm : 1 to 31 days or off | Output : USB communication interface | Memory : Stores up to 500 data sets | Connector : BNC, 6-pin mini-DIN, 3.5 mm jack socket | Display : Custom LCD (125 × 100 mm) | Power Supply : 5V DC | Dimension (L × W × H) : 210 × 188 × 60 mm | Weight : 1.5 kg |
|
Dissolved Oxygen Mode |
Dissolved Oxygen Range : 0.00 to 20.00 mg/L | Dissolved Oxygen Accuracy : ±0.2 mg/L / ±2.0 % | Dissolved Oxygen Resolution : 0.01 / 0.1, selectable | Dissolved Oxygen Calibration Points : 1 or 2 points | % Saturation Range : 0.0 to 200.0 % saturation | Pressure Correction : 60.0 to 112.5 kPa / 450 to 850 mmHg, manual | Salinity Correction : 0.0 to 50.0 g/L, manual |
|
Multi-parameters are used in research testing, agriculture , quality analysis of water, wastewater treatment, other general liquids across water plants, food and beverages production units, laboratories, and institutes. |