Benchtop Conductivity Meter LD-LBCM-A15
Benchtop Conductivity Meter LD-LBCM-A15 with 1 to 3 points push button conductivity calibration, automatically recognizes calibration standards. With setup menu, it does setting of 6 parameters calibration points, temperature units and others. 7 inch TFT display shows settings and measurement values. Temperature compensation by manual & automatic method improves the accuracy of conductivity meter.
SKU Code: LD-LBCM-A15
Also Available in below capacities
Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity measurement range : 0.000 μS/cm to 3000mS/cm
Conductivity Mode :
- Specifications
- Product Applications
|
|
Memory |
Stores Up to 1000 data sets |
Output |
USB interface |
Weight |
1.7 kg |
Display |
LCD |
TDS Mode |
TDS measurement Range | 0 to 10.00, 100.0, 1000 mg/L, 10.00, 200.0 g/L | TDS Accuracy | ± 1 % F.S. | TDS Factor | 0.01 to 1.00 (default 0.5) | TDS Resolution | 0.01 / 0.1 / 1 or automatic |
|
Connector |
6-pin mini plug |
Power supply |
DC 12V, Power Adapter |
Salinity Mode |
Salinity Range | 0.00 to 80.00 ppt / 0.00 to 42.00 psu / 0.00 to 8.00% | Salinity Resolution | 0.01 | Salinity Accuracy | ± 1 % F.S. |
|
Reset Function |
Yes |
Resistivity Mode |
Resistivity Range | 0.00 to 30.00 MΩ | Resistivity Resolution | 0.01 / 0.1 / 1 or automatic | Resistivity Accuracy | ± 1 % F.S. |
|
Temperature Mode |
Temperature range | 0 to 105°C, 32 to 221°F | Temperature accuracy | ± 0.5 °C | Temperature resolution | ± 1 °C | Temperature calibration points | 1 point | Temperature coefficient | 0.0 to 10.0 % per °C | Temperature Compensation Range | 0 to 100°C / 32 to 212°F |
|
Conductivity Mode |
Conductivity Range | 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm | Conductivity Accuracy | ±0.5 % F.S. | Conductivity Resolution | 0.001/0.01/0.1/1, automatic | Conductivity Calibration Points | 1 to 3 Points | Conductivity Solutions | 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm | Conductivity Temperature coefficient | 0.0 to 10.0 %/°C | Compensation coefficient | Linear / Non-Liner / Pure Water | Cell Constant | 2-Pole Electrode K=0.1, 1, 10 or 4-Pole Electrode | Reference temperature | 20 or 25°C |
|
Data Hold Function |
Manual or Automatic Endpoint Detection |
Stability Criteria |
Standard or High |
Calibration Due Alarm |
1 to 31 Days |
Dimension (L × W × H) |
240 × 220 × 80 mm |
Used for quality checking of water on different parameters across research, QC labs, water management plants and others production units. |