Benchtop Multi-parameter Water Quality Meter LD-LMPWM-A41 with large backlit LCD (125 × 100 mm) display, measures pH, ORP(mV), relative mV, temperature and Ion concentration of the sample. Equipment saves space of the benchtop by combining multiple parameters in one unit. With expanded memory, it stores and recalls up to 500 data sets. Calibration due reminder informs the operator to calibrate the meter regularly. Setup menu allows you to set the number of calibration points, stability criteria, temperature unit, date and time, auto-power off, etc. USB communication interface for data transfer and timed interval readings. Sensor of the ORP electrode is with platinum black coating to promote speed of reaction at the electrode.
SKU Code: LD-LMPWM-A41
Memory | Stores up to 500 data sets |
Output | USB communication interface |
Weight | 1.5 kg |
Display | Custom LCD (125 × 100 mm) |
pH Mode | |
pH Range | -2.000 to 20.000 pH |
Connector | BNC, 3.5 mm jack socket |
Temperature | |
pH Accuracy | ±0.002 pH |
ORP(mV) Mode | |
Power supply | 5V DC power adapter |
ORP(mV) Range | -1999.9 to 1999.9 mV |
pH Resolution | 0.001 / 0.01 / 0.1 pH, selectable |
Reset Function | Yes |
ORP(mV) Accuracy | ±0.2 mV |
Ion Concentration | |
Data Hold Function | Manual / Auto-read measurement endpoint |
ORP(mV) Resolution | 0.1 / 1 mV, selectable |
Stability Criteria | Low / High |
pH Buffer Solutions | USA / NIST / DIN / 2 custom buffers |
Other Specifications | |
Calibration Due Alarm | 1 to 31 days or off |
pH Calibration Points | 1 to 5 points |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Ion Concentration Range | 0.001 to 19999 ppm, mg/l, mol/l, mmol/l (depending on the range of ISE) |
ORP(mV) Measurement Modes | Relative / Absolute mV |
Ion Concentration Accuracy | ±0.5% F.S. (monovalent), ±1% F.S. (divalent) |
ORP(mV) Calibration Points | 1 point |
Ion Concentration Resolution | 0.001, 0.01, 0.1, 1, automatic |
ORP(mV) Calibration Solutions | 0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000 |
Temperature Compensation Mode | Manual or Automatic |
Temperature Measurement Range | 0 to 105°C / 32 to 221°F |
Temperature Compensation Range | 0 to 100°C / 32 to 212°F |
Temperature Measurement Accuracy | ±0.5°C / ±0.9°F |
Temperature Measurement Resolution | 0.1°C/°F |
Ion Concentration Calibration Points | 2 to 5 Points |
Temperature Measurement Calibration Points | 1 Point |
Multi-parameters are used in research testing, agriculture , quality analysis of water, wastewater treatment, other general liquids across water plants, food and beverages production units, laboratories, and institutes. |